CFPNT - MXSE 55 B.C., 796496

  • MSDS: CFPNT
  • Manufacturer: FIBERITE INC
  • Product Name: MXSE 55 B.C., 796496
  • National Stock Number: 8305-00N079709
Product Identification

Product ID:MXSE 55 B.C., 796496
MSDS Date:12/04/1996
FSC:8305
NIIN:00N079709
MSDS Number: CFPNT

Responsible Party
FIBERITE INC.
501 WEST THIRD ST
WINONA, MN 55987
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 507-452-8092

Cage: JO527

Contractor
FIBERITE INC.
WINONA, MN 55987 US

Telephone: 507-452-8092

Cage: JO527

Ingredients

SILICA, FUMED.; (SILICA FIBER, AMORPOUS)

CAS: 7631-86-9

Fraction By Weight: 40-70%

OSHA PEL 20 MPPCF TWA (MFR)

ACGIH TLV: 10 MG/M3 TWA (MFR)


PHENOLIC RESIN

Fraction By Weight: 15-40%

OSHA PEL N/K

ACGIH TLV: N/K


PHENOL (SARA 302/313) (CERCLA)

CAS: 108-95-2

RTECS: SJ3327000

Fraction By Weight: 1-5%

OSHA PEL S, 5 PPM

ACGIH TLV: S, 5 PPM; 9495

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


FORMALDEHYDE (SARA 302/313) (CERCLA)

CAS: 50-00-0

RTECS: LP8925000

Fraction By Weight: 0.1-1%

OSHA PEL SEE 1910.1048

ACGIH TLV: C 0.3 PPM, A2; 9495

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


2-BUTANONE; (METHYL ETHYL KETONE) (SARA 313) (CERCLA)

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: 1-5%

OSHA PEL 200 PPM

ACGIH TLV: 200 PPM/300STEL;9495

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ETHYL ALCOHOL (ETHANOL)

CAS: 64-17-5

RTECS: KQ6300000

Fraction By Weight: 1-5%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM; 9495


INHAL MAY CAUSE NASAL AND RESP IRRIT, HDCH, NAUS,

RTECS: 9999999ZZ


CAUSED MINOR EMBRYOTOXIC EFTS IN LAB ANIMALS WHEN

RTECS: 9999999ZZ


AND RESP IRRIT, HDCH, EXCITATION FOLLOWED BY NARC

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:NO INFO IS AVAIL ON THIS MIX AS A
WHOLE. THE INFO PRESENTED IS BASED ON EACH OF THE COMPONENTS
PRESENT AT CONC > 1% (0.1% FOR CARCINS). ING 2: MAY CAUSE SKIN
IRRIT & POSS DERM. SENSITIVE INDIVIDUALS M AY EXPER ALLERGIC SKIN
RXN. ING 3: RESIDUAL MAY CAUSE RESP & EYE IRRIT/BURNING. MAY BURN,
ANESTH/BE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:FORMALDEHYDE: IARC MONO, SUPP, VOL 7, PG
211, 1987: GRP 2B. NTP 7TH ANNUAL RPT ON CARCINS, 1994: ANTIC TO
(SUP DAT)
Effects of Overexposure:HLTH HAZ:ABSORBED THRU SKIN CAUSING SYSTEMIC
POIS. INGESTION MAY CAUSE LIVER AND KIDNEY INJURY. ING 4: HIGHLY
IRRIT IN SOME INDIVIDUALS TO UPPER RESP TRACT AND EYES AT CONC BTWN
0.5-2.0 PPM. ALTHOUGH NOT LIKELY ROUTE OF EXPOS, IF INGEST MAY
INDUCE IRRIT AND INFLAMM OF MOUTH, THROAT, AND STOMACH, NAUS,
VOMIT, (SUP DAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST:CALL MD IMMEDIATELY . INHAL:REMOVE TO FRESH AIR.
PROVIDE OXYG IF NEC. IF NOT BRTHG, GIVE MOUTH TO MOUTH
RESUSCITATION. CALL MD. EYES: IRRIGATE W/H*20 FOR MIN 15 MINS. SEEK
MED ATTN. SKIN: WASH THOROUGHLY W/SOAP & H*20. SEEK MED ATTN IF
IRRIT DEVELOPS. WASH CONTAMINATED CLOTHING BEFORE REUSE.

Fire Fighting

Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL, WATER.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . EXOTHERM FIGHTING PROCEDURES: DISSIPATE HEAT BY
SPREADING MATL APART AND DOUSING W/H*20. (SUP DAT)
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:CONTAMINATED MATERIAL SHOULD BE PICKED UP AND
DISPOSED OF PROPERLY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:THE USE OF GLOVES WHEN HNDLG UNCURED
MATL IS STRONGLY RECOMD. AVOID SKIN CONTACT! STORE AT OR BELOW 50
DEG F.
Other Precautions:WHEN PROCESSING AT ELEVATED TEMPS, PROVIDE ADEQ VENT
TO CONTROL PROCESSING VAPORS AND FUMES. THIS PROD CNTNS UNCURED
RESIN(S). CURING SHOULD ONLY BE DONE IN WELL-VENT/CLOSED SYS.

Exposure Controls

Respiratory Protection:USUALLY NOT NEEDED. USE NIOSH APPRVD RESP IF
EXPOS LIMITS ARE EXCEEDED. IN ABSENCE OF ADEQ GEN/LOC VENT PROVIDE
NIOSH APPRVD RESPS TO MINIMIZE EXPOS TO GASES, VAPORS, OR
PARTICULATES RELEASED DURING L AY-UP, MOLDING OR MACHINING
OPERATIONS.
Ventilation:PROVIDE GOOD GEN/LOC EXHST VENT TO CTL AIRBORNE LEV < EXPOS
LIM, PARTICULARLY WHERE GRINDING/HEATING OPERATIONS OCCUR.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYE WASH & DELUGE SHOWER . CLEAN
BODY-COVERING CLOTHING TO MINIMIZE EXPOSURE.
Work Hygienic Practices:IN ACCORDANCE WITH GOOD INDUSTRIAL HYGIENE,
HANDLE WITH CARE AND AVOID UNNEC PERSONAL CONTACT.
Supplemental Safety and Health
FIRE FIGHTING PROC: CNTN EMISSIONS USING LOCAL EXHST. EXPLAN OF CARCIN:
BE CARCIN. OSHA REG: CFR 29 1910.1048. ANIMAL: NASAL. EFTS OF
OVEREXP: AND SEV ABDOM PAIN. ING 1: PRLNGD EXPOS TO HIGH ATMS CON
CS OF RESPIRABLE DUST MAY CAUSE NON-PROGRESSIVE FIBROSIS ON LUNGS,
DOES NOT CAUSE SILICOSIS. ING 5 VAPORS: (ING 7)

Chemical Properties

Spec Gravity:1.5 CURED MATL
Appearance and Odor:IMPREGNATED FIBERS; SLIGHT ODOR
Percent Volatiles by Volume:<2

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, STRONG BASES, STRONG OXIDIZERS.
Stability Condition to Avoid:AVOID HEATING MATERIAL IN BULK.
Hazardous Decomposition Products:DENSE SMOKE, ACRID VAPORS AND FUMES,
HYDROCARBONS OF VARIABLE COMPOSITION, COX, NOX.
Conditions to Avoid Polymerization:HAZARDOUS POLYMERIZATION CAN OCCUR
WITH RAPID OR EXCESSIVE HEATING. AVOID HEATING MATERIAL IN BULK.

Disposal

Waste Disposal Methods:DISPOSE OF I/A/W LOCAL, STATE & FEDERAL
REGULATIONS. QUESTIONS CONCERNING DISPOSAL SHOULD BE DIRECTED TO
FIBERITE'S SAFETY, HEALTH, AND ENVIRONMENTAL AFFAIRS DEPT FOR
EVALUATION ON A CASE-BY-CASE BASI S.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.